The identifier (ID) is the serial number of the device. It is located under the QR code on the body, board, and packaging of the device.

ID at the bottom of the box

ID under the lid

The ID can also be found in the device states in the Ajax app.

  1. Sign in to the Ajax app.
  2. Select the required hub from the list if you have several of them or if you are using a PRO app.
  3. Go to the Devices menu.
  4. Select a device from the list. Device ID information is located at the bottom of the status screen.
Copied

At the moment, this possibility is not provided.

Copied

The bus power supply test shows which devices and on which Fibra lines may have insufficient power supply.

If the power supply is insufficient, we cannot guarantee the stable operation of the security system.

Before installing wired devices, we recommend calculating the line length using an online calculator.

If a certain device is not getting enough power supply, you can:

  • Connect devices that are not powered enough to another Fibra line.
  • Reduce the number of devices on the Fibra line that is not powered enough.
  • Replace high-power consuming devices with lower-power devices if facility configuration allows.

After any change in the device configuration at the facility, we recommend re-testing the bus power supply.

Copied

When installing Fibra devices, be sure to observe the polarity and order of the wires connected.

Copied

When installing devices near power cables, we recommend using a shielded cable to lay the Fibra wired line.

Copied

Fibra devices work on 24V⎓ voltage.

The minimum allowable voltage for Fibra devices to operate is 8 V⎓. Such a voltage may be at the end of a line to which many devices are connected.

If the voltage on a device is below 8V⎓, a fault counter will appear on that device, and the Voltage field in the device States will turn to red color.

Thus, we recommend that you perform a Bus Power Supply Test after installing the devices to ensure that they work correctly.

Copied

You can install outdoors only the StreetSiren Fibra siren.

All remaining Fibra devices are designed for indoor installation. Outdoor installation may cause malfunctions and false alarms.

Detailed installation guidelines for each Fibra device are available in the User Manual for that device.

Copied

Ajax security system provides several tests to check the operation of wired devices.

Fibra Signal Strength Test checks the device signal strength and stability at the intended installation location.

Detection Zone Test checks how the device responds to alarms (the test is only available for Ajax security detectors).

Volume Level Test — checks the siren volume sound at the intended installation location (the test is only available for Ajax sirens).

Bus Power Supply Test simulates the maximum possible power consumption of the system: detectors generate alarms, keypads are activated, sirens are turned on. If the system successfully passed the test, then all its wired devices will have enough power supply in any situation.

During the bus power supply test, connected wired sirens are activated.

We recommend that you perform all security system tests after installing the devices to ensure that they work correctly.

Copied

Fibra devices are connected to the hub using a Star topology. Wired devices are connected to the line in parallel. The line cannot branch.

ajax fibra topology

Connecting Fibra devices using a Ring topology will be implemented in the next OS Malevich updates.

Copied

The maximum length of a wired Fibra line is 2,000 meters.

The appropriate wired line length depends on the number and type of connected devices and the type of used cable.

Therefore, before installing wired devices, we recommend calculating the line length using an online calculator.

And after installing the devices, perform a Fibra Signal Strength Test and a Bus Power Supply Test to make sure the system is working correctly.

Copied

Fibra devices are connected using a 4-wire cable.

We recommend using the following types of conductors:

  • U/UTP cat.5 twisted pair (4 × 2 × 0.51).
  • ALARM signal cable (4 × 0.22).
Copied

The firmware version can be found in the device states in the Ajax app.

  1. Sign in to the Ajax app.
  2. Select the required hub from the list if you have several of them or if you are using a PRO app.
  3. Go to the Devices menu.
  4. Select a device from the list. The firmware version information is located on the status screen at the bottom.
Copied

Featured articles

How to disable device events once for a time the armed mode is active

What is Fibra Signal Strength Test

Tips for installing and configuring wired Fibra devices

Spelling error report

The following text will be sent to our editors: