What is Detection Zone Test

Updated
  1. Ajax appDevices Select relevant deviceSettings Detection Zone TestStart
ajax detection zone test

The detection zone tests allow you to determine the distance at which the detector will detect alarms. In test mode, the light indicator lights up continuously, switching off during the alarm. In order to determine the detection area, use the device light indication as a guide.

Device Procedure of testing

In order to check the opening detector at the suggested installation place, open and close the door/window. If the detector responds to all actions, it is installed correctly.

If the third-party wired device is connected to the opening detector’s external contact, each device should be checked separately. For example, check the opening detector first and then the connected device.

In order to check the motion detector, walk across the room, following the LED reaction, and determine the detector detection area. Maximum motion detection distance is 12 meters.

If the detector does not always respond to the motion during the test, it should be mounted elsewhere.

Contains motion detector and sensor masking tests.

  • In order to check the motion detector, walk within sight of the detector while observing the LED and determine the detection zone of the detector. If the detector does not always respond to the motion during the test, it should be mounted elsewhere.
  • In order to check the masking sensors, block the view of the detector in the zone of its detection with a possible obstacle. For example, use a sheet of A4 paper. Contact the Ajax support service if the detector does not respond to masking.
Contains motion detector and sensor masking tests.

  • In order to check the motion detector, walk within sight of the detector while observing the LED and determine the detection zone of the detector. If the detector does not always respond to the motion during the test, the camera should be mounted elsewhere.
  • In order to check the masking sensors, block the view of the detector in the zone of its detection with a possible obstacle. For example, use a sheet of A4 paper. Contact the Ajax support service if the detector does not respond to masking.

In order to check the detector at the intended installation location, cross the detection zone while observing the LED reaction. Follow these steps for the right and left sides of the detector.

If the detector does not respond to motion as required, adjust its settings on each side:

  • horizontal viewing angle shift by 3 degrees — Beam direction switch;
  • near zone detection — Near area detection switch;
  • setting the detection distance — Detection distance scrollbar.

In order to check the masking sensors, block the view of the detector in the zone of its detection with a possible obstacle on each side. For example, use a sheet of A4 paper. Contact the Ajax support service if the detector does not respond to masking

The glass break detector registers an alarm if it detects two components: a low-frequency component (sound of impact against glass) and a high-frequency component (impacts of shards against each other).

Therefore, in order to check the glass break detector, bang the hard surface with your fist (preferably the glass plane, but without breaking it). The detector must respond to the low-frequency sound of the impact against the glass, turning off the LED for 0.2 s. If this happens, throw a metal object (for example, a spoon) at the hard surface or hit it with a glass tumbler within one and a half seconds. The detector will turn off the LED for a second; this means that in armed mode the glass break detector will normally respond to the glass breaking. Decrease the detector sensitivity and keep checking until the detector stops responding to the alarm sounds. After this, bring the sensitivity level back to the previous limit at which the detector responded normally. In this way, the probability of the detector being falsely triggered is minimized and at the same time provides reliable protection for the facility.

To provide maximum protection against false triggering, turn on all appliances that usually operate in the room: generators, air conditioners, etc.

If switching on these devices intermittently causes the detector to activate, its installation place should be chosen more carefully.

If the third-party wired device is connected to the glass break detector’s external contact, each device should be checked separately. For example, check the glass break detector first and then the connected device.

Combines MotionProtect and GlassProtect testing procedure.

If the detector responds poorly to the alarms during the tests, it is necessary to choose another location.

 