Partner Portal

Superior Hub Hybrid (4G) (without casing)

Hybrid control panel designed for installation in Case D (430). Works with Fibra and Jeweller devices. Connectable via Ethernet and two SIM cards (2G/3G/LTE).

FAQ

The light guide and the LED board are included in the Superior Hub Hybrid (4G) (without casing) complete set.

To install the light guide and the LED board in Case (430):

  1. Prepare a hole for the light guide. Drill the Ø10 mm hole in the bottom or side of the casing near the places where the LED board will be installed.
  2. Install the light guide and the LED board from the Superior Hub Hybrid (4G) (without casing) complete set.
  3. Connect the LED board to the appropriate hub terminal.
Copied

Both Superior Hub Hybrid (4G) and Superior Hub Hybrid (4G) (without casing) have almost the same technical characteristics and settings, differing only in the following:

  1. Superior Hub Hybrid (4G) (without casing) is sold separately as a board without casing and must be installed in Case D (430) using Module Holder (type B). Use Case configurator to get the most optimal placement of your Fibra devices in the casing.

    Superior Hub Hybrid (4G) is sold in its casing and can’t be installed at the premises without it.

  2. Superior Hub Hybrid (4G) has two tamper buttons notify of attempts to remove the casing lid or detach the control panel casing from the surface. Superior Hub Hybrid (4G) (without casing) also has two tampers, but they are unused in this version of the control panel. Instead of them, the Superior Hub Hybrid (4G) (without casing) board has a connector for attaching the tamper board.
  3. The Superior Hub Hybrid (4G) (without casing) board has an SMA female connector to connect Ajax ExternalAntenna. We recommend installing Ajax ExternalAntenna in areas with poor cellular signal reception.

    Ajax ExternalAntenna is sold separately.

  4. The Superior Hub Hybrid (4G) (without casing) board has a connector for attaching the external LED to the hub. The light guide and the LED board are included in the Superior Hub Hybrid (4G) (without casing) complete set.
Copied

Superior Hub Hybrid (4G) (without casing) must be installed into Case D (430) using Module Holder (type B), which is sold separately. How to install Superior Hub Hybrid (4G) (without casing) into Case D — please read the Superior Hub Hybrid (4G) (without casing) user manual.

Copied

Spelling error report