Calibration of the Superior DoorProtect G3 Fibra magnetic masking sensor is important for the correct operation of the device and instant detection of the attempt to use fraudulent magnets.
The sensor should be calibrated immediately after adding it to the system or if the installation location has been changed. Calibration is performed when the primary detector’s contact is closed.
When the sensor is being calibrated, the system registers the magnetic field value at the detector’s installation site. This value will be taken as normal. The detector compares the current magnetic field value with the one recorded during calibration and identifies the differences.
If an intruder attempts to mask Superior DoorProtect G3 Fibra in the armed mode with a fraudulent magnet, the detector will instantly send an alarm to the hub. The hub will activate the sirens connected to the system, trigger scenarios, and notify users and the security company.