OS Malevich is a real-time operating system that manages the operation of Ajax security systems control panels and range extenders.
OS Malevich is regularly updated with new features for PRO and end-users. This article contains all the updates of OS Malevich with the description of new features they added to the system.
OS Malevich 2.26
Release start: November 2024
◇ Notification of device triggering during the detection zone test. The app informs the engineer when a device is triggered, which is useful when the LED indication is not visible.
◇ Support for new devices and features that will become available in upcoming apps release.
OS Malevich 2.25
Release start: October 2024
◇ Support for telephony settings. Available in Ajax PRO apps if at least one SpeakerPhone Jeweller is added to the system (Hub → Settings → Telephony settings).
◇ Support for new devices and features that will become available in upcoming apps release.
◇ Support for new devices and features that will become available in upcoming apps release.
OS Malevich 2.24
Release start: August 2024
◇ Support for new devices and features that will become available in upcoming apps releases.
OS Malevich 2.23
Release start: July 2024
◇ Support for new devices and features that will become available in upcoming apps release.
OS Malevich 2.22
Release start: June 2024
◇ Feature for delaying notifications of external power loss (Hub → Settings → Service).
◇ Support for new features and devices, that will become available with upcoming apps release.
OS Malevich 2.21
Release start: April 2024
◇ Extended Alarm confirmation setting for hubs via the alarm confirmation zone (cross zone).
Available only in PRO apps: Hub → Settings → Service → Alarm confirmation.
◇ Support for the new system devices.
OS Malevich 2.20
Release start: March 2024
◇ Battery saving mode* for hubs that are temporarily not connected to an external power supply (Hub → Settings → Service → Battery Power Saver).
◇ Support for new features and devices, that will become available with upcoming apps release.
OS Malevich 2.19
Release start: January 2024
◇ Battery saving mode* for hubs that are temporarily not connected to an external power supply (Hub → Settings → Service → Battery Power Saver).
◇ For fire detectors from AC line, added the fallback channel for interconnected fire alarm, which allows the alarm to be propagated even if devices lost connection with a hub. You can set the option in hub settings:
Hub → Settings → Service → Fire detectors settings.
◇ For motion detectors with Photo on Demand feature support added the Photo by schedule.
◇ For wired devices connected to integration modules, added new types of alarms and notifications: glass break, high and low temperatures, vibration, masking, duress code (opening).
◇ Support for new features and devices, that will become available with upcoming apps release.
* Feature is not available for Hub 2 Plus Jeweller. It will be delivered in future firmware updates.
OS Malevich 2.18
Release start: November 2023
◇ Support the new system devices and minimal updates for better performance.
◇ Added the ability to select in the settings whether to display the ReX 2 malfunction counter in the Devices tab if it lost connection with the hub via radio channels.
OS Malevich 2.17
Release start: October 2023
◇ For keypad access codes, added response unit codes, that activates only after alarm for pre-set time. Available in PRO apps.
◇ Added KeyArm Zone that allows switching system arming modes with a third-party device connected to Transmitter or MultiTransmitter.
◇ In hub settings, Jeweller/Fibra menu, added an option that enables notifying of radio jamming with alarm.
◇ The test results after self-test of fire detectors will now be transmitted to CMS via Contact ID and SIA protocols.
◇ Possibility not to send alarm to CMS if the system was disarmed during the alarm transmission delay (PRO apps → Hub → Settings → Service → Arming/Disarming Settings).
◇ Support for the new system devices.
OS Malevich 2.16
Release start: July 2023
◇ Support for the new system devices, including Superior product line.
◇ Updated settings for delays when entering/leaving. Now in each security device settings, it is possible to set the operating mode of the device in case of an alarm: instant alarm, alarm after a delay when entering/leaving ends, following the delays of other detectors.
◇ For Hub Hybrid, the support or connecting lines via Ring topology has been added. The ring connection occupies two line outputs of the hub and physically protects the Fibra line. In case of a ring break, not a single device will be disabled: the connection will form two separate lines that will continue operating as usual and transmit events from connected devices to the hub. At the same time, a security company and users will receive a notification about the line break.
◇ In Monitoring Station settings of hubs using SIA direct connection, the ability to set a unique IP address for each alarm channel has been added. To configure the hub settings, in the Ajax apps: Hub → Settings → Monitoring Station → One IP address for all alarm channels. When the option is disabled, the user can specify the primary and secondary IP addresses for the alarm channels.
◇ Supervising feature for Button Jeweller, Button S Jeweller. The system performs a daily check of the button’s battery state.
◇ Other minor fixes and improvements.
OS Malevich 2.15.4
Release start: November 2023
◇ This OS Malevich version provides support for FireProtect 2 RB (Heat/Smoke/CO) Jeweller and FireProtect 2 RB (Heat/Smoke) Jeweller detectors.
OS Malevich 2.15.2
Release start: June 2023
◇ For all system users, added the ability to run Detection Zone Test from hub settings.
◇ The ability to deactivate devices for one time until the system is disarmed.
◇ Support for the new security system devices.
◇ This OS Malevich version provides system stability and support for all security system features.
OS Malevich 2.15
Release start: April 2023
◇ Support for the new security system devices.
◇ For LifeQuality added the support of charts, showing the fluctuation of air quality values. Please note that only measurements recorded after hub updates to version 2.15 will be shown in charts.
◇ Sound indication for keypads according to UL certification requirements. With the appropriate settings, the keypads beep to notify users about a low battery of any device in the system or the currently offline devices.
Enable the feature in hub settings in a PRO app: Hub → Settings → Service → Sounds and Alerts.
Please note that the feature will only be available for the keypads’ latest firmware versions.
◇ The new type of push notifications in User settings (Hub → Settings → Users → User name → Notification settings). Now it is possible to determine if the user will receive the push notifications about automation devices triggering and notifications of air quality values fluctuation.
◇ In notifications from automation devices, added the information of the triggering reason. The device is switched on/off:
- by the user in the app;
- by scenario;
- by the user pushing the device button.
New notifications are currently not supported in the PRO Desktop app.
◇ Other minor fixes and improvements.
◇ This OS Malevich version provides system stability and support for all security system features.
OS Malevich 2.14
Release start: November 2022
◇ Scenario by temperature change. Now in automation devices settings, you can set the reaction of the device (switch on, switch off, switch the state) to the change of temperature measured by other system detectors.
◇ New security system devices support.
◇ Bug fixes in operation of Keypad Access Codes feature with Group mode enabled.
◇ This OS Malevich version provides system stability and support for all security system features.
OS Malevich 2.13.1
Release start: July 2022
◇ Keypad access codes to arm/disarm the system. You can create such codes in hub settings for temporary users of the system or for users without account. One code can be used for all keypads in the system, and you and the security company will always know which code was used and when it was used.
◇ Now the range extender of the second generation, connected via Ethernet, and devices paired with it can be transferred to a new hub during data import even if the connection via Jeweller is unstable.
◇ This OS Malevich version provides system stability and support for all security system features.
OS Malevich 2.13
Release start: May 2022
◇ Ethernet as an additional communication channel for the range extender of the second generation.
◇ New Privacy menu in hub settings and a Privacy Manager position for hub admins.
◇ New security system devices support. We will notify you as soon as they become available for purchase.
◇ New Privacy menu in hub settings and a Privacy Manager position for hub admins. These two features allow managing access of system users to surveillance cameras streams.
◇ New security system devices support. We will notify you as soon as they become available for purchase.
OS Malevich 2.12.1
Release start: December 2021
Chime is available for indoor sirens starting from version 5.55.1.0, and for outdoor sirens starting from version 3.73.1.0.
◇ Other minor fixes and improvements.
OS Malevich 2.12
Release start: September 2021
◇ Silent mode for sirens. Flexible adjustment of sirens signalling in Night Mode. To use this feature, go to siren settings and select Beeps Settings.
◇ Chime. A sound that sirens connected to the system emit when a door opens. Chime alerts those inside that someone has either entered or exited the home. The option works only for disarmed systems and devices that are not in Always Active mode. To set the Chime, enable the corresponding setting both for sirens and opening detectors.
Chime is available for HomeSiren starting from version 5.55.1.0. Currently, StreetSiren and StreetSiren DoubleDeck don’t support the Chime feature.
◇ Restriction of rights to interconnected alarms muting. With the new Residential fire alarm system feature users can postpone alarm propagation and mute the interconnected alarm only in groups they have access rights to.
Enable the feature in hub settings: Hub → Settings → Service → Fire detectors settings → Residential fire alarm system.
◇ Updated operating algorithm for server connection loss notifications. You can choose whether to receive notifications of hub-server connection loss through selected communicating channels: Ethernet, cellular, Wi-Fi.
To adjust corresponding notifications, go to hub settings: Service → Server connection.
◇ Other minor fixes and improvements.
◇ Updated operating algorithm for server connection loss notifications. You can choose whether to receive notifications of hub-server connection loss through selected communicating channels: Ethernet, cellular, Wi-Fi.
To adjust corresponding notifications, go to hub settings: Service → Server connection.
◇ Other minor fixes and improvements.
OS Malevich 2.11
Release start: April 2021
◇ Modified operation algorithm of pulse detectors connected to MultiTransmitter. Pulse detector alarms are currently not displayed as malfunctions in Ajax apps, when the security system is disarmed.
OS Malevich 2.10
Release start: November 2020
Users can initiate remote arming from the Ajax app — the system will be armed if no detectors have been triggered within the specified time. Also, users can initiate arming using a control device (SpaceControl or KeyPad) — the system will be armed by triggering the device marked as Second-Stage Device. For example, when closing a door on which DoorProtect is installed.
Find this feature in service settings of the hub (Hub — Settings — Service — Arming/Disarming Process).
◇ Transmitting the alarm restoration to an ARC. The feature enables configuring when the hub transmits the restoration code to a monitoring station. Two options are available: when restoring or when disarming.
The feature is configured in the monitoring station parameters (Hub — Settings — Monitoring Station — Alarm Restore on ARC).
◇ Alarm confirmation. The system sends a separate Alarm Confirmation event to a monitoring station if several selected devices have been triggered within the specified time.
Find this feature in service settings of the hub (Hub — Settings — Service — Alarm confirmation).
◇ Restoration after alarm. The feature does not allow arming the system if an alarm has been activated previously. To arm the system, it must be restored by an authorized user (PRO or administrator). The types of alarms that require restoration are specified when configuring the feature.
Find this feature in service settings of the hub (Hub — Settings — Service — Restore After Alarm).
The right to restore is configured for each user separately (Hub — Settings — Users — User Settings — Restore After Alarm).
◇ Selective system integrity check. Administrator or PRO user can choose the hub states that are included in the integrity check before arming the system.
Find this feature in service settings of the hub (Hub — Settings — Service — System integrity check).
◇ Delay for alarm transmission when disarming. The feature allows postponing the alarm transmission after the end of the entry delay if the security system has not been disarmed.
Please note that PD 6662:2017 allows disarming the system with a KeyPad only when an alarm is already sent. To disarm the system before sending an alarm, enable the Allow disarming with keypad option.
Find this feature in service settings of the hub (Hub — Settings — Service — Arming/Disarming Process).
◇ Devices auto deactivation. The feature is designed to ignore detector notifications if it has not returned to its initial state within a specified time, or after a specified number of alarms. The timer applies only to bistable detectors (e.g., DoorProtect, LeaksProtect).
Find this feature in service settings of the hub (Hub — Settings — Service — Device auto deactivation).
◇ After-alarm indication. If the system has activated an alarm, the sirens flash twice every few seconds until the system is disarmed.
In the settings, you can configure the types of alarms, which sirens will indicate: confirmed alarms, unconfirmed alarms, or lid opening. Please note that the siren after-alarm indication is inapplicable to detectors in Always Active mode.
Find this feature in service settings of the hub (Hub — Settings — Service — Siren Settings).
◇ Delay for the FireProtect interconnected alarm. The function allows users to postpone other fire detectors’ alarm for 1 to 5 minutes. During this time, the alarm signal is not transmitted to a monitoring station.
To postpone the interconnected alarm, use the app, tap on the logo of the triggered detector, or use Button, KeyPad Plus and KeyPad with the appropriate settings.
Find this feature in service settings of the hub (Hub — Settings — Service — Fire detectors settings).
◇ Switching the automation device state by a Button command. When creating a scenario for controlling Relay/Socket/WallSwitch via Button, users can choose not only the specific Switch on/off action but set the contacts’ state to switch to the opposite.
A scenario is created in the Button settings.
◇ New SMS languages: Bulgarian, Croatian, Hungarian, Macedonian, Romanian, Serbian, and Slovenian.
OS Malevich 2.9
Release start: August 2020
◇ Possibility to seamlessly replace the old hub with a new one. No reconfiguration, adding users and devices.
To use the function, go to the Import Data menu in the settings of the new hub. For data transferring to occur, both hubs should have OS Malevich no lower than 2.9.
◇ Temporary deactivation function for devices. A damaged or improperly installed device that bothers users and security companies with false notifications can be excluded from the system, without deleting the device and its settings. The new menu Temporary deactivation is available in the device settings.
◇ Pulse mode for Socket and WallSwitch: when the state of contact changes only for the time specified in the settings and then returns to its initial position.
The pulse duration Relay, WallSwitch and Socket can be from 0.5 to 255 seconds. You can also configure the initial state of the contacts — normally closed or open (NC/NO).
This allows you to adjust the pulse accordingly to the task of the automation device. The pulse mode is available in the settings of devices with a firmware version of no lower than 5.54.1.0.
◇ Customized alarm types for Button and Transmitter. The text of notification in applications and the event code transmitted to the security company’s monitoring software depend on the type of alarm. There are five types of alarms available for customizing: intrusion, fire, medical, panic button, gas leak. The type of alarm is set in the device settings.
◇ Transmission of the user’s coordinates to a security central monitoring station by pressing the panic button in the app. This function allows you to inform the security company about an emergency outside the facility protected by Ajax. And other users of the system can now copy the geolocation coordinates or go to the online map from the notification in the event feed.
◇ Additional protection against accidental clicks of SpaceControl. Now in SpaceControl settings with firmware version no lower than 5.54.1.0, you can enable response only by double or long press.
◇ Adjustable brightness of the Socket LED frame. Now, bright light will not bother you in bedrooms and rooms where the indication is unnecessary.
In Socket settings with firmware version no lower than 3.55.0, you can select full, low brightness or switch off the LED frame.
◇ Possibility to disable the alarm indication of security detectors. In the detector settings, you can now disable the LED indicator’s flashing in case of an alarm.
The setting is available for DoorProtect, DoorProtect Plus, MotionProtect, MotionProtect Plus, CombiProtect, MotionProtect Outdoor, MotionCam and GlassProtect with a firmware version no lower than 5.55.0.0, and MotionProtect Curtain with a firmware version no lower than 6.53.1.1.
◇ Notifying about switching on/off and resetting a hub to the factory settings. This feature provides more information to users and security companies to monitor the security system.
OS Malevich 2.8.1
Release start: November 2019
Scenarios automate your routines and help your security system to actively resist threats. Program a flood prevention system to shut off the water at the first signs of leakage. Create a heating schedule or set up the electric locks to activate when the security system is armed.
◇ Visual alarm verification
With the new MotionCam detector you’ll see exactly what triggered the motion alarm: a babysitter that forgot to disarm the house, a hyperactive dog, or a burglar that climbed through the window.
- First photo delivered in under 9 seconds
- Up to 4 years of operation on the pre-installed batteries
- Communicates at a distance of up to 1700 m from the hub
◇ Button — smart home remote control
Now you can use Button as a wireless panic button or as a remote control for the automation devices: Relay, WallSwitch or Socket. Choose how they would react to a short or long press.
◇ Multi ReX
Hub Plus, Hub 2 and Hub 2 Plus support up to 5 ReX range extenders, which expands a potential coverage area of the security system to up to 35 km2. ReX boosts the autonomy of security and makes it more reliable by integrating the connected detectors into an autonomous group within the system.
OS Malevich 2.8
Release start: November 2019
OS Malevich 2.7
Release start: February 2019
◇ Personal SpaceControl. Assign the key fob to one specific user to get personalized notifications about arming and disarming.
◇ MotionProtect Outdoor power supply. Check the status of the external power supply in the mobile app and get instant notifications about power outages.
OS Malevich 2.6
Release start: August 2018
◇ Passcodes for everyone. KeyPad now can recognize users by personal passcodes. And every user can set a passcode whichever he likes.
◇ Double reliability. You can add two IP address for sending alarms to the central monitoring station directly.
◇ Control everything. The actions for adding and deleting groups, rooms, users, devices, cameras will be displayed in the notifications feed.
◇ More options. We have moved the entrance/leaving delays to the device’s settings. They can be applied to perimetral arming.
◇ Flexible access. Now you can disable the list of devices and all notifications for some users.
OS Malevich 2.5
Release start: December 2017
OS Malevich 2.4
Release start: December 2017
◇ More users and more rooms
◇ Phone calls for all users
◇ Keyboard support
◇ Siren activation flexibility
◇ A fire detection network
◇ Test fire detectors directly from the application
◇ Improved protection against false fire alarms
◇ Disable the remote control alarm button
◇ Reducing dependence on the cloud
◇ New software distribution system