KeyPad TouchScreen Fibra and KeyPad TouchScreen Jeweller have the same features and settings, but they have the following differences.

KeyPad TouchScreen Fibra KeyPad TouchScreen Jeweller
Connection Wired Wireless
Communication technology Fibra

Jeweller

Wings

Maximum communication range Up to 2000 meters¹ Up to 1700 meters
Number of personal codes² 50 200
Number of duress codes² 50 200
Number of codes for unregistered people² 50 99
Power supply Powered by the Fibra line, has a rechargeable backup battery 2 × LTO AA 6 × AA battery
Requires external power for firmware update  No Yes
¹ When connected using the U/UTP Cat.5 twisted pair cable.
² The number of codes depends on the hub model.
Copied

The external power for KeyPad TouchScreen Fibra is for:

  • The Always active display function.
  • Constant LED indication.

The external power supply also reduces the power consumption from the hub¹ and is recommended for audible signals longer than 30 seconds.

¹ External power supply does not increase the maximum communication range.
Copied

KeyPad TouchScreen Fibra is supplied by the Fibra line from the hub and has a rechargeable backup battery (2 × LTO AA pre-installed). This battery provides power to the device during screen activation or any other energy-consuming interaction.

Copied

In the states of each Fibra device, you can see its loop (zone) number as well as number of the line to which it is connected. When using the Ring topology, you can see to which ring the device is connected.

If the device is added to the hub, for example, using LineSupply (75 W) Fibra, you can see the module name and the output line number in the states.

Copied

The lines power test shows which devices and on which Fibra lines may have insufficient power supply.

If the power supply is insufficient, we cannot guarantee the stable operation of the security system.

Before installing wired devices, we recommend calculating the line length using an online calculator.

If a certain device is not getting enough power supply, you can:

  • Add devices to the hub through the LineSupply Fibra module.
  • Connect devices that are not powered enough to another Fibra line.
  • Reduce the number of devices on the Fibra line that is not powered enough.
  • Replace high-power consuming devices with lower-power devices if facility configuration allows.

After any change in the device configuration at the facility, we recommend re-testing the lines power supply.

Copied

When installing Fibra devices, be sure to observe the polarity and order of the wires connected.

Copied

When installing devices near power cables, we recommend using a shielded cable to lay the Fibra wired line.

Copied

Fibra devices work on 24V⎓ voltage.

The minimum allowable voltage for Fibra devices to operate is 8 V⎓. Such a voltage may be at the end of a line to which many devices are connected.

If the voltage on a device is below 8V⎓, a fault counter will appear on that device, and the Voltage field in the device States will turn to red color.

Thus, we recommend that you perform a Lines Power Test after installing the devices to ensure that they work correctly.

Copied

You can install outdoors only the StreetSiren Fibra and StreetSiren DoubleDeck Fibra sirens.

All remaining Fibra devices are designed for indoor installation. Outdoor installation may cause malfunctions and false alarms.

If you need to connect third-party wired outdoor detectors to the Ajax system, use the MultiTransmitter Fibra or Transmitter Fibra integration modules.

Detailed installation guidelines for each Fibra device are available in the User Manual for that device.

Copied

Ajax security system provides several tests to check the operation of wired devices.

Fibra Signal Strength Test checks the device signal strength and stability at the intended installation location.

Detection Zone Test checks how the device responds to alarms (the test is only available for Ajax security detectors).

Volume Level Test — checks the siren volume sound at the intended installation location (the test is only available for Ajax sirens).

Lines Power Test simulates the maximum possible power consumption of the system: detectors generate alarms, keypads are activated, sirens are turned on. If the system successfully passed the test, then all its wired devices will have enough power supply in any situation.

During the lines power test, connected wired sirens are activated.

We recommend that you perform all security system tests after installing the devices to ensure that they work correctly.

Copied

Fibra devices are connected to the hub using Beam (Radial wiring), Ring, and Tree topologies.

As depicted in the diagram, wired devices should be connected to the Fibra line sequentially, one after the other, without any branching.

Line branching and the Tree topology are only allowed when using LineSplit Fibra.

The Ring topology is also available. If the line breaks, the devices will still be connected to the hub via the Beam (Radial wiring) connection, continuing to transmit events and alarms to the hub.

We recommend connecting devices using the Ring topology if possible. This improves the sabotage protection of the line.

Keep in mind, the output lines created when using LineSplit Fibra or LineProtect Fibra don’t support the Ring topology.

Learn more

Copied

The maximum length of a wired Fibra line is 2,000 meters.

The appropriate wired line length depends on the number and type of connected devices and the type of used cable.

Therefore, before installing wired devices, we recommend calculating the line length using an online calculator.

And after installing the devices, perform a Fibra Signal Strength Test and a Lines Power Test to make sure the system is working correctly.

Copied

Fibra devices are connected using a 4-wire cable.

We recommend using the following types of conductors:

  • U/UTP cat.5 4×2×0.51 mm (24 AWG) cable, copper conductor.
  • 4×0.22 mm² signal cable, copper conductor.